MCTRL300 Setup Manual PDF: Nova M3 Configuration Guide

NovaStar manual

MCTRL300 Setup Manual PDF: Nova M3 Configuration Guide

NovaStar did not publish a separate current hardware manual for the MCTRL300. The verified Nova M3 system manual names the MCTRL300 in its supported sending-device list and explains the NovaLCT-Mars setup workflow used with it.

This PDF is the NovaStar Nova M3 system manual. It explicitly lists MCTRL300, but it is not a standalone hardware specification sheet.

What the MCTRL300 setup manual covers

Screen connection

Connect the controller or sending card to the computer, receiving cards and LED cabinets in the correct order.

Cabinet configuration

Load or create the receiving-card file, set cabinet dimensions and confirm the data path before mapping the full screen.

Screen mapping

Assign cabinets to Ethernet outputs, check the connection order and save the finished configuration to the hardware.

Checks and troubleshooting

Confirm communication, source timing and saved settings before the system is installed or returned to service.

MCTRL300 setup sequence

1

Check the hardware

Use the datasheet to confirm input format, output count, power and capacity before opening the software.

2

Connect the control computer

Use the documented USB or network control path and confirm that the device appears in NovaLCT.

3

Configure one cabinet first

Load a known receiving-card file or complete Smart Setting, then test one cabinet before mapping the wall.

4

Map and save the screen

Build the cabinet connection map, send it to the hardware and save a backup of the working configuration.

MCTRL300 specifications and limits

Use the specifications table for hardware limits. The manual explains the setup process; it does not replace the model datasheet.

Document MCTRL300 Specifications V2.4.1
Video input 1× single-link DVI, 8-bit RGB 4:4:4
Maximum input 1920×1200@60Hz; custom examples 3840×600 and 548×3840
LED outputs 2× Gigabit Ethernet
Loading 1.3 million pixels total; 650,000 pixels per output
Power / dimensions 100–240 VAC, 3 W; 204×160×48 mm